(800) WE-REPAIR

937-3724

Service Repair Products Repair Parts Contact Us

Equipment Service

NURSING AND REHAB EQUIPMENT

  • Alternating pressure mattresses
  • Beds
  • Defibrillators
  • E.K.G.s
  • Oxygen concentrators
  • Patient lifts
  • Scales
  • Suction pumps
  • Nebulizers
PHYSICAL THERAPY EQUIPMENT
  • Chiropractic tables
  • E-stim units
  • Fluidotherapy units
  • Hot/cold pack units
  • Treatment tables & chairs
  • Whirlpools
MEDICAL, SURGICAL AND VETERINARY EQUIPMENT
  • Autoclaves
  • Centrifuges
  • Coposcopes
  • Defibrillators
  • E.K.G.s
  • Electro-cautery units
  • Emergency power systems
  • Examination tables
  • Gas evacuations systems
  • Microscopes
  • Midmark tables
  • Monitors
  • Ophthalmoscopes
  • Otoscopes
  • Power examination tables
  • Pulse-oximeters
  • Scales
  • Sterilizers
  • Stretchers
  • Suction pumps
  • Surgical lights
  • Surgical microscopes
  • Table Re-upholstery
  • Treadmills
  • Treatment tables & chairs
  • Ultrasonic cleaners
  • Ultrasonic scalers
  • Ultrasounds
  • Vacuum pumps
DENTAL EQUIPMENT
  • Cavitrons
  • Dental air compressors
  • Dental chairs
  • Dental handpieces
  • Dental lights
  • Film processors
  • Suction pumps
  • Vacuum pumps

 

EZ9

EZ9 Features:

  • Closed door active drying system to maintain sterility and ensure efficient drying of packs and pouches.
  • High efficiency air pump circulates hot air after the sterilization cycle for fast drying.
  • Hepa filter 0.2 µm air filter (replaceable).
  • Pre-loaded cycles for: unwrapped instruments, wrapped/packs, glassware and additional drying cycle.
  • All program parameters can be customized and stored.
  • Automatic shut off at the end of both the sterilization and dry cycles.
  • Audible and visual cycle interruption alert.
  • Double safety locking device prevents door from opening while chamber is pressurized.
  • Low water sensor prevents activation of sterilization cycle when there is insufficient water in the chamber or reservoir.
  • Constant monitoring of temperature and pressure for sterilization.
  • Power outage recovery system.
  • Door design prevents steam from coming in contact with control panel.
  • Optional internal printer documents: date, time, temperature and pressure.
  • 510k clearance for dental handpieces.
  • Drain valve is located on the front, allowing for quick and easy draining of water reservoir.
  • International certifications.
  • 2 year parts and labor warranty.

 

SALES - SERVICE - PREVENTIVE MAINTENANCE